Inductive
loops or "sensing loops" as they are commonly referred
to, have become an integral part of automatic gate systems and other
aspects of our everyday life. For example, every time you pull up
to a stoplight, you "trigger" a loop, which in turn engages
a timer or switching device to change the lights and get you on
your way. Loops are used to stop or reverse a moving gate, to allow
free exit from or entrance to a site, or as an "arming loop"
to allow entrance with the use of a transmitter or some other access
control device.
A loop is made from a continuous run
of wire with no splices, which is typically wound in a rectangular
shape and saw cut into the existing pavement. In some instances
prefabricated or "pre-formed" loops can be installed before
paving or pouring concrete on the roadway. The ends of the wire
are brought back to the gate operator and attached to a loop detector.
The lead-in or "home run" from the corner of the loop
to the detector must be twisted a minimum of five times per foot.
The detector powers the loop causing a magnetic field around the
wire. The loop then tunes to a resonate frequency and the detector
constantly monitors the frequency for changes. When a vehicle enters
the loop, the frequency increases causing the detector to send an
output to the gate operator.
The size of the loop depends on the
job conditions. Variables include driveway size and the typical
size of vehicles expected to pass through the gate system. When
sizing your loop, a good rule of thumb to follow is: The height
of detection is equal to approximately 2/3 the length of the short
side of the loop. For example, a 4' x 8' loop will give a detection
height between 2-1/2 and 2-3/4 feet. For high bed vehicle detection,
the typical loop size is 6' x 8' .
The number of turns in the loop is determined
by the size of the loop. Multiplying the length by the width will
give you the loop area in square feet. A loop area of 12 to 60 square
feet requires four turns. An area of 60 to 240 square feet requires
three turns. Adding turns to a loop does not increase the sensitivity,
but will make the loop more stable if the lead-in is longer than
400' . The size of the loop also determines the loop placement.
The larger the loop, the greater the spacing must be between the
loop and the gate. Essentially, loops should be placed a minimum
of 4’ from the gate.
When connecting more than one loop to
a detector, always connect the loops in series. The correct phasing
of the loops is important if the loops are close to each other.
The sensitivity setting on the loop detector should be increased
when adding loops to the same detector.
It is important to use the correct wire
in your loop installation. A 14, 16 or 18 AWG stranded wire can
be used. The insulation on the wire should be XLPE (cross-linked
polyethylene). This insulation has a high resistance to water, heat,
abrasions, oils and gasoline, each of which can cause false detections.
There are several factors to consider
when actually installing the loop. For example, the wire should
be buried a minimum of 1" below the roadway, but no more than
6" deep, and should be secured in place by a backer rod and
then the desired sealant for your application. In addition, when
saw cutting for your loop, cut the corners at a 45 degree angle
instead of 90 degrees to reduce stress and abrasion of the wire.
If the wire is cut or nicked, it will eventually cause false detections
which in turn cost you service calls. Finally, when using more than
one loop detector in the same installation (i.e. a reversing loop
and a free exit loop) the frequency settings on the detectors should
be set differently to avoid "cross talk" which can cause
false detections.
Wire connections are also critical to
the installation procedure. Whenever possible, the connections should
be soldered together instead of using a wire nut or crimp connector.
Loose connections can cause false detections and over time may show
signs of corrosion.
When trouble shooting loops, the best
tool to use is a megohm meter. After disconnecting the loop from
the detector, place one lead of the meter to one of the lead wires
of the loop and the other to earth ground. The resistance should
be greater than 100 megohms. A reading between 50 and 100 megohms
means the wire insulation may be nicked or cut and the loop is questionable.
If the resistance is less than 50 megohms, the loop is shorted to
ground, and must be replaced.
Most loop detectors have built in diagnostics
which can identify problems in the detection system. A series of
blinking LED’s is an indication of possible loop problems.
If this occurs, the detector must be reset to continue normal operation
of your system. Full diagnostic detectors are available for problem
sites. These units can keep track of shorts or intermittent problems
that may temporarily correct themselves, and should help determine
the condition of the loop. Hopefully, the information provided above
clarifies any questions involving loop detectors and their installation.
The following types of loops are commonly
used:
Reversing Loop: used to stop or reverse
direction of an automatic gate or barrier operator.
Free Exit (Egress) or Free Entry (Ingress):
used to open an automatic gate or raise the arm of a barrier operator.
Shadow Loop: used in swing gate applications.
This loop is placed inside the swing area of the gate and is only
active when the gate is in the full open position and will not allow
the swing gate to close.
Close Loop: used in barrier operator
applications. This loop is placed directly under the arm of the
operator. When the vehicle clears the loop, the arm automatically
lowers.
Arming loop: used to control access
to a site. The vehicle must drive onto the arming loop before using
an access device such as a transmitter or card.
Click here for installation details |